Project Description

CASE STUDY

Thomas Fields, Buxton

Project

Dyer Environmental Controls Ltd supplied, installed and commissioned a new natural smoke ventilation system at Buxton Extra Care.

Thomas Fields is a Housing & Care 21 project developed in partnership with High Peak Borough Council, Derbyshire County Council and Homes England.

The development facilitates people over the age of 55, containing 53 two bedroom apartments with a range of on-site amenities. It offers independent living with access to on-site care.

System

Dyer’s system has been configured to be a “stand alone” Manual Opening Vent (MOV) system and will work independently from the fire alarm system. In the event of activation the system will send a signal to the fire alarm panel.

The D+H drives require 2 cores to operate but by adding a third core paired with an end of line resistor, Dyer enabled the cable to be monitored for any breaks or damage.

  • The principle of operation is the same for each floor:
  • The fire-man’s override unit is activated, the local vent will open.
  • If the fire-man’s override is activated on the smoke shaft, the local damper will open along with the head of shaft and local staircase. All other dampers on the shaft will close and become locked out.
  • The control panel will send a signal to the fire alarm panel to indicate activation.
  • The red light on the fire-man’s override switch adjacent to the activation will illuminate.
  • The system operates on natural ventilation via local thermostats within the corridors. The thermostats are discrete as well as tamper-proof

Dyer’s system complies to the following:

  • Building Regulations Approved Documents Part B
  • Compliance with Smoke Ventilation Control Panels – EN12101.10
  • Chain Drive Actuators for smoke ventilation – EN12101.2
  • Fire Protected Cable Installation – BS8519

RELATED CASE STUDIES

LATEST TWEETS…

@dyerenvironment

- 2 days ago

Dyer's case studies provide real insight into our range of work. See details on our natural day-to-day, natural smoke & mechanical smoke ventilation solutions - https://t.co/1zAvVV5ibV https://t.co/tMJPR2V8a4
h J R
@dyerenvironment

- 5 days ago

Dyer's Knowledge Centre provides access to useful information on our systems and solutions. Our Troubleshooting Guides are available to assist installers on our most popular control systems. https://t.co/YVrfdc1rP6 https://t.co/REfcSKkikb
h J R
@dyerenvironment

- 6 days ago

Our latest case study on smoke shaft and NSHEV window ventilation systems can be viewed @BarbourNews https://t.co/4TgAYCmjn5 https://t.co/bK7rnJOsnS
h J R
@dyerenvironment

- 8 days ago

@BarbourNews: @DyerEnvironment were specified to provide their EN Certified natural smoke ventilation systems for Balmoral Place. Read the full case study here: https://t.co/DODGz1UfdI #dyer #dyerenvironmentalcontrols #ventilation #ventilationsystem https://t.co/IUvvQBH8NM
h J R
@dyerenvironment

- 13 days ago

Dyer's latest case study highlights our smoke shaft and NSHEV window ventilation systems at Balmoral Place Extra Care. The case study is available to view on our site - https://t.co/zijjlTOhUa https://t.co/kEKv7ethFB
h J R